{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-27982","id":"CVE-2023-27982","title":"A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause ma…","description":"A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(I","descriptionLong":"A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).","published":"2023-03-21T00:00:00.000Z","updated":"2026-06-17T05:46:18.447Z","reserved":"2023-03-09T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"schneider"},"metrics":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"schneider"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"se.com"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"}],"rating":"high","products":["Schneider Electric IGSS Data Server(IGSSdataServer.exe)","Schneider Electric IGSS Dashboard (DashBoard.exe)","Schneider Electric Custom Reports (RMS16.dll)"],"affectedProducts":[{"vendor":"Schneider Electric","product":"IGSS Data Server(IGSSdataServer.exe)","defaultStatus":null,"versions":[{"version":"V","status":"affected","lessThanOrEqual":"16.0.0.23040","versionType":"custom"}],"platforms":[]},{"vendor":"Schneider Electric","product":"IGSS Dashboard (DashBoard.exe)","defaultStatus":null,"versions":[{"version":"V","status":"affected","lessThanOrEqual":"16.0.0.23040","versionType":"custom"}],"platforms":[]},{"vendor":"Schneider Electric","product":"Custom Reports (RMS16.dll)","defaultStatus":null,"versions":[{"version":"V","status":"affected","lessThanOrEqual":"16.0.0.23040","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-345"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf","tags":["x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00403,"epssPercentile":0.35348,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-27982","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-27982","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-27982","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-27982","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}