{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-2262","id":"CVE-2023-2262","title":"Rockwell Automation Select Logix Communication Modules Vulnerable to Email Object Buffer Overflow","description":"\n\n\nA buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.\n\n\n\n","descriptionLong":"\n\n\nA buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.\n\n\n\n","published":"2023-09-20T15:20:23.700Z","updated":"2026-06-17T05:52:07.910Z","reserved":"2023-04-24T21:35:54.200Z","status":"Modified","rejected":false,"assigner":"Rockwell","metric":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"Rockwell"},"metrics":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"Rockwell"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"rockwellautomation.com"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"NVD"}],"rating":"critical","products":["Rockwell Automation 1756-EN2T Series A, B, C","Rockwell Automation 1756-EN2T Series D","Rockwell Automation 1756-EN2TK Series A, B, C","Rockwell Automation 1756-EN2TXT Series A, B, C","Rockwell Automation 1756-EN2TXT Series D","Rockwell Automation 1756-EN2TP Series A","Rockwell Automation 1756-EN2TPK Series A","Rockwell Auotmation 1756-EN2TPXT Series A","Rockwell Automation 1756-EN2TR Series A, B","Rockwell Automation 1756-EN2TR Series C","Rockwell Automation 1756-EN2TRK Series A, B","Rockwell Automation 1756-EN2TRK Series C","Rockwell Automation 1756-EN2TRXT Series A, B","Rockwell Automation 1756-EN2TRXT Series C","Rockwell Automation 1756-EN2F Series A, B","Rockwell Automation 1756-EN2F Series C","Rockwell Automation 1756-EN2FK Series A, B","Rockwell Automation 1756-EN2FK Series C","Rockwell Automation 1756-EN3TR Series A","Rockwell Automation 1756-EN3TR Series B","Rockwell Automation 1756-EN3TRK Series A","Rockwell Automation 1756-EN3TRK Series B"],"affectedProducts":[{"vendor":"Rockwell Automation","product":"1756-EN2T Series A, B, C","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2T Series D","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TK Series A, B, C","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TXT Series A, B, C","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TXT Series D","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TP Series A","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TPK Series A","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Auotmation","product":"1756-EN2TPXT Series A","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TR Series A, B","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TR Series C","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TRK Series A, B","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TRK Series C","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TRXT Series A, B","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2TRXT Series C","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2F Series A, B","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2F Series C","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2FK Series A, B","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN2FK Series C","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN3TR Series A","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN3TR Series B","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.003"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN3TRK Series A","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=5.008 & 5.028"}],"platforms":[]},{"vendor":"Rockwell Automation","product":"1756-EN3TRK Series B","defaultStatus":"unaffected","versions":[{"status":"affected","version":"<=11.002"}],"platforms":[]}],"packages":[],"cwes":["CWE-121","CWE-787"],"aliases":[],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140786","tags":["x_transferred","Permissions Required","Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total"},"epss":0.01292,"epssPercentile":0.70899,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-2262","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-2262","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-2262","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-2262","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}