{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-1966","id":"CVE-2023-1966","title":"CVE-2023-1966","description":"Instruments with Illumina Universal Copy Service v1.x and\nv2.x contain an unnecessary privileges vulnerability. An unauthenticated\nmalicious actor could upload and execute code remotely at the operating system\nlevel, which could allow an attacker to change settings, configurations,\nsoftware, or access sensitive data on the affected product.\n\n\n\n\n\n","descriptionLong":"Instruments with Illumina Universal Copy Service v1.x and\nv2.x contain an unnecessary privileges vulnerability. An unauthenticated\nmalicious actor could upload and execute code remotely at the operating system\nlevel, which could allow an attacker to change settings, configurations,\nsoftware, or access sensitive data on the affected product.\n\n\n\n\n\n","published":"2023-04-28T18:06:51.431Z","updated":"2026-06-17T05:29:09.353Z","reserved":"2023-04-10T14:50:41.262Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.1","score":7.4,"vector":"CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"high","source":"icscert"},"metrics":[{"version":"3.1","score":7.4,"vector":"CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"high","source":"icscert"},{"version":"3.1","score":7.4,"vector":"CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"high","source":"hq.dhs.gov"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"NVD"}],"rating":"high","products":["Illumina  iScan Control Software","Illumina  MiniSeq Control Software","Illumina  iSeq 100","Illumina  MiSeq Control Software","Illumina  MiSeqDx Operating Software","Illumina  NextSeq 500/550 Control Software","Illumina  NextSeq 550Dx Control Software","Illumina  NextSeq 550Dx Operating Software","Illumina  NextSeq 1000/2000 Control Software","Illumina  NovaSeq 6000 Control Software","Illumina  NovaSeq Control Software"],"affectedProducts":[{"vendor":"Illumina ","product":"iScan Control Software","defaultStatus":"unaffected","versions":[{"status":"affected","version":"4.0.0"},{"status":"affected","version":"4.0.5"}],"platforms":[]},{"vendor":"Illumina ","product":"MiniSeq Control Software","defaultStatus":"unaffected","versions":[{"status":"affected","version":"2.0 "}],"platforms":[]},{"vendor":"Illumina ","product":"iSeq 100","defaultStatus":"unaffected","versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Illumina ","product":"MiSeq Control Software","defaultStatus":"unaffected","versions":[{"status":"affected","version":"4.0 (RUO Mode)"}],"platforms":[]},{"vendor":"Illumina ","product":"MiSeqDx Operating Software","defaultStatus":"unaffected","versions":[{"status":"affected","version":"4.0.1 "}],"platforms":[]},{"vendor":"Illumina ","product":"NextSeq 500/550 Control Software","defaultStatus":"unaffected","versions":[{"status":"affected","version":"4.0"}],"platforms":[]},{"vendor":"Illumina ","product":"NextSeq 550Dx Control Software","defaultStatus":"unaffected","versions":[{"status":"affected","version":"4.0 (RUO Mode)"}],"platforms":[]},{"vendor":"Illumina ","product":"NextSeq 550Dx Operating Software","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"1.3.1","status":"affected","version":"1.0.0 ","versionType":"custom"},{"status":"affected","version":"1.3.3 "}],"platforms":[]},{"vendor":"Illumina ","product":"NextSeq 1000/2000 Control Software","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"1.4.1","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"Illumina ","product":"NovaSeq 6000 Control Software","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"1.7 ","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"Illumina ","product":"NovaSeq Control Software","defaultStatus":"unaffected","versions":[{"status":"affected","version":"1.8"}],"platforms":[]}],"packages":[],"cwes":["CWE-250","CWE-269"],"aliases":[],"references":[{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-117-01","tags":["x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html","tags":["vendor-advisory","x_transferred","Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00916,"epssPercentile":0.60881,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-1966","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-1966","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-1966","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-1966","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}