{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2023-1487","id":"CVE-2023-1487","title":"Lespeed WiseCleaner Wise System Monitor IoControlCode WiseHDInfo64.dll 0x9C40A0E0 denial of service","description":"A vulnerability, which was classified as problematic, has been found in Lespeed WiseCleaner Wise System Monitor 1.5.3.54. This issue affects the function 0x9C40208C/0x9C402000/0x9C402084/0x9C402088/0x9C402004/0x9C4060C4/0x9C4060CC/0x9C4060D0/0x9C4060D4/0x9C40A0DC/0x9C40A0D8/0x9C40A0DC/0x9C40A0E0 in the library WiseHDInfo64.dll of the component IoControlCode Handler. The manipulation leads to denia","descriptionLong":"A vulnerability, which was classified as problematic, has been found in Lespeed WiseCleaner Wise System Monitor 1.5.3.54. This issue affects the function 0x9C40208C/0x9C402000/0x9C402084/0x9C402088/0x9C402004/0x9C4060C4/0x9C4060CC/0x9C4060D0/0x9C4060D4/0x9C40A0DC/0x9C40A0D8/0x9C40A0DC/0x9C40A0E0 in the library WiseHDInfo64.dll of the component IoControlCode Handler. The manipulation leads to denial of service. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The identifier VDB-223373 was assigned to this vulnerability.","published":"2023-03-18T21:00:04.837Z","updated":"2026-06-17T05:28:04.643Z","reserved":"2023-03-18T20:02:47.861Z","status":"Modified","rejected":false,"assigner":"VulDB","metric":{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"VulDB"},"metrics":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"VulDB"},{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"vuldb.com"},{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"NVD"},{"version":"3.0","score":5.5,"vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"VulDB"},{"version":"2.0","score":4.6,"vector":"AV:L/AC:L/Au:S/C:N/I:N/A:C","rating":"medium","source":"VulDB"},{"version":"2.0","score":4.6,"vector":"AV:L/AC:L/Au:S/C:N/I:N/A:C","rating":"medium","source":"vuldb.com"}],"rating":"medium","products":["Lespeed WiseCleaner Wise System Monitor"],"affectedProducts":[{"vendor":"Lespeed","product":"WiseCleaner Wise System Monitor","defaultStatus":null,"versions":[{"version":"1.5.3.54","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-404"],"aliases":[],"references":[{"url":"https://vuldb.com/?id.223373","tags":["vdb-entry","technical-description","x_transferred","Permissions Required","Third Party Advisory"]},{"url":"https://vuldb.com/?ctiid.223373","tags":["signature","permissions-required","x_transferred","Permissions Required","Third Party Advisory"]},{"url":"https://github.com/zeze-zeze/WindowsKernelVuln/tree/master/CVE-2023-1487","tags":["related","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://drive.google.com/file/d/1zk_ErtD34TBnQu8VGTUZKQpGGVDaUR1y/view","tags":["exploit","x_transferred","Exploit"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":true,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00348,"epssPercentile":0.29026,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2023-1487","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-1487","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2023-1487","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2023-1487","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}