{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-46144","id":"CVE-2022-46144","title":"SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >=…","description":"A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2A","descriptionLong":"A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial  interface irresponsive.","published":"2022-12-13T00:00:00.000Z","updated":"2026-06-17T05:11:17.670Z","reserved":"2022-11-28T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"siemens"},"metrics":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","rating":"high","source":"siemens"},{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"high","source":"siemens.com"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"siemens"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"siemens.com"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"NVD"}],"rating":"high","products":["Siemens SCALANCE SC622-2C","Siemens SCALANCE SC626-2C","Siemens SCALANCE SC632-2C","Siemens SCALANCE SC636-2C","Siemens SCALANCE SC642-2C","Siemens SCALANCE SC646-2C","Siemens SCALANCE WAM763-1","Siemens SCALANCE WAM766-1","Siemens SCALANCE WAM766-1 (US)","Siemens SCALANCE WAM766-1 EEC","Siemens SCALANCE WAM766-1 EEC (US)","Siemens SCALANCE WUM763-1","Siemens SCALANCE WUM766-1","Siemens SCALANCE WUM766-1 (USA)"],"affectedProducts":[{"vendor":"Siemens","product":"SCALANCE SC622-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC622-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"V2.3","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC626-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC626-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"V2.3","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC632-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC632-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"V2.3","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC636-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC636-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"V2.3","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC642-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC642-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"V2.3","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC646-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE SC646-2C","defaultStatus":"unknown","versions":[{"status":"affected","version":"V2.3","lessThan":"V3.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE WAM763-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE WAM766-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE WAM766-1 (US)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE WAM766-1 EEC (US)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE WUM763-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE WUM763-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE WUM766-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE WUM766-1 (USA)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.0.0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-664"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf","tags":["x_transferred","Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-413565.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-690517.html","tags":["x_transferred"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00966,"epssPercentile":0.62457,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-46144","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-46144","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-46144","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-46144","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}