{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-43768","id":"CVE-2022-43768","title":"SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versi…","description":"A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP ","descriptionLong":"A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product.","published":"2023-04-11T09:02:51.623Z","updated":"2026-10-23T23:10:00.157Z","reserved":"2022-10-26T11:27:16.347Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C","rating":"high","source":"siemens"},"metrics":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C","rating":"high","source":"siemens"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"siemens.com"}],"rating":"high","products":["Siemens SIMATIC CP 1242-7 V2","Siemens SIMATIC CP 1243-1","Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)","Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)","Siemens SIMATIC CP 1243-7 LTE EU","Siemens SIMATIC CP 1243-7 LTE US","Siemens SIMATIC CP 1243-8 IRC","Siemens SIMATIC CP 1542SP-1","Siemens SIMATIC CP 1542SP-1 IRC","Siemens SIMATIC CP 1543SP-1","Siemens SIMATIC CP 443-1","Siemens SIMATIC CP 443-1 Advanced","Siemens SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL","Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC","Siemens SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL","Siemens SIPLUS NET CP 1242-7 V2","Siemens SIPLUS NET CP 443-1","Siemens SIPLUS NET CP 443-1 Advanced","Siemens SIPLUS S7-1200 CP 1243-1","Siemens SIPLUS S7-1200 CP 1243-1 RAIL","Siemens SIPLUS TIM 1531 IRC","Siemens TIM 1531 IRC"],"affectedProducts":[{"vendor":"Siemens","product":"SIMATIC CP 1242-7 V2","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 1243-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 1243-7 LTE EU","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 1243-7 LTE US","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 1243-8 IRC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 1542SP-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 1542SP-1 IRC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 1543SP-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 443-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 443-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC CP 443-1 Advanced","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CP 1543SP-1 ISEC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS NET CP 1242-7 V2","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS NET CP 443-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS NET CP 443-1 Advanced","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CP 1243-1","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1200 CP 1243-1 RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.4.29","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS TIM 1531 IRC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3.6","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"TIM 1531 IRC","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.3.6","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-770"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf","tags":["x_transferred","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-139628.html","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-566905.html","tags":["x_transferred"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial"},"epss":0.00954,"epssPercentile":0.62105,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-43768","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-43768","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-43768","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-43768","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}