{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-43439","id":"CVE-2022-43439","title":"POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All…","description":"A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions < V2.50), SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (","descriptionLong":"A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions < V2.50), SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.10), SICAM T (All versions < V3.0). Affected devices do not properly validate the Language-parameter in requests to the web interface on port  443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.","published":"2022-11-08T00:00:00.000Z","updated":"2026-06-17T05:06:32.723Z","reserved":"2022-10-19T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"3.1","score":9.9,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","rating":"critical","source":"siemens"},"metrics":[{"version":"3.1","score":9.9,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C","rating":"critical","source":"siemens"},{"version":"3.1","score":9.9,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"siemens.com"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"}],"rating":"critical","products":["Siemens POWER METER SICAM Q100","Siemens SICAM P850","Siemens SICAM P855","Siemens SICAM T"],"affectedProducts":[{"vendor":"Siemens","product":"POWER METER SICAM Q100","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.50","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"POWER METER SICAM Q100","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.50","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"POWER METER SICAM Q100","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.50","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"POWER METER SICAM Q100","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V2.50","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P850","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM P855","defaultStatus":"unknown","versions":[{"status":"affected","version":"All versions < V3.10"}],"platforms":[]},{"vendor":"Siemens","product":"SICAM T","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"V3.0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-20"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-572005.pdf","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf","tags":["x_transferred","Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf","tags":["x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-572005.html","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-570294.html","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-887249.html","tags":[]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-471761.html","tags":[]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.02057,"epssPercentile":0.81709,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-43439","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-43439","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-43439","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-43439","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}