{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-38773","id":"CVE-2022-38773","title":"Affected devices do not contain an Immutable Root of Trust in Hardware","description":"Affected devices do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot image of the device and execute arbitrary code.","descriptionLong":"Affected devices do not contain an Immutable Root of Trust in Hardware. With this the integrity of the code executed on the device can not be validated during load-time. An attacker with physical access to the device could use this to replace the boot image of the device and execute arbitrary code.","published":"2023-01-10T11:39:37.547Z","updated":"2026-06-17T04:57:08.797Z","reserved":"2022-08-26T13:13:01.075Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"3.1","score":4.6,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:T/RC:C","rating":"medium","source":"siemens"},"metrics":[{"version":"3.1","score":4.6,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:T/RC:C","rating":"medium","source":"siemens"},{"version":"3.1","score":4.6,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","rating":"medium","source":"siemens.com"},{"version":"3.1","score":6.8,"vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"medium","source":"NVD"}],"rating":"medium","products":["Siemens SIMATIC Drive Controller CPU 1504D TF","Siemens SIMATIC Drive Controller CPU 1507D TF","Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN","Siemens SIMATIC S7-1500 CPU 1510SP-1 PN","Siemens SIMATIC S7-1500 CPU 1511-1 PN","Siemens SIMATIC S7-1500 CPU 1511C-1 PN","Siemens SIMATIC S7-1500 CPU 1511F-1 PN","Siemens SIMATIC S7-1500 CPU 1511T-1 PN","Siemens SIMATIC S7-1500 CPU 1511TF-1 PN","Siemens SIMATIC S7-1500 CPU 1512C-1 PN","Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN","Siemens SIMATIC S7-1500 CPU 1512SP-1 PN","Siemens SIMATIC S7-1500 CPU 1513-1 PN","Siemens SIMATIC S7-1500 CPU 1513F-1 PN","Siemens SIMATIC S7-1500 CPU 1513R-1 PN","Siemens SIMATIC S7-1500 CPU 1515-2 PN","Siemens SIMATIC S7-1500 CPU 1515F-2 PN","Siemens SIMATIC S7-1500 CPU 1515R-2 PN","Siemens SIMATIC S7-1500 CPU 1515T-2 PN","Siemens SIMATIC S7-1500 CPU 1515TF-2 PN","Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1517H-3 PN","Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP","Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP","Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP","Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","Siemens SIMATIC S7-1500 CPU 1518HF-4 PN","Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP","Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP","Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK","Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK","Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN","Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN","Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN","Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN","Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN","Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL","Siemens SIPLUS ET 200SP CPU 1510SP-1 PN","Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL","Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN","Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL","Siemens SIPLUS ET 200SP CPU 1512SP-1 PN","Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL","Siemens SIPLUS S7-1500 CPU 1511-1 PN","Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL","Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL","Siemens SIPLUS S7-1500 CPU 1511F-1 PN","Siemens SIPLUS S7-1500 CPU 1513-1 PN","Siemens SIPLUS S7-1500 CPU 1513F-1 PN","Siemens SIPLUS S7-1500 CPU 1515F-2 PN","Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL","Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL","Siemens SIPLUS S7-1500 CPU 1515R-2 PN","Siemens SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL","Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP","Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL","Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL","Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP","Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL","Siemens SIPLUS S7-1500 CPU 1517H-3 PN","Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP","Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP","Siemens SIPLUS S7-1500 CPU 1518HF-4 PN"],"affectedProducts":[{"vendor":"Siemens","product":"SIMATIC Drive Controller CPU 1504D TF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC Drive Controller CPU 1507D TF","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511C-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511C-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511T-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1511TF-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512C-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512C-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1513R-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515R-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515T-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1515TF-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516T-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1516TF-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517H-3 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517T-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1517TF-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518HF-4 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518T-4 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518TF-4 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1510SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS ET 200SP CPU 1512SP-1 PN RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511-1 PN TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1511F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1513F-1 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515R-2 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1517H-3 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518F-4 PN/DP","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518HF-4 PN","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-1326"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-482757.pdf","tags":["x_transferred","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-482757.html","tags":["x_transferred"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00305,"epssPercentile":0.23682,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-38773","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-38773","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-38773","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-38773","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}