{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-36361","id":"CVE-2022-36361","title":"LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE…","description":"A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24R","descriptionLong":"A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.","published":"2022-10-11T00:00:00.000Z","updated":"2026-06-17T04:53:19.430Z","reserved":"2022-07-21T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C","rating":"critical","source":"siemens"},"metrics":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C","rating":"critical","source":"siemens"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"siemens.com"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"NVD"}],"rating":"critical","products":["Siemens LOGO! 12/24RCE","Siemens LOGO! 12/24RCEo","Siemens LOGO! 230RCE","Siemens LOGO! 230RCEo","Siemens LOGO! 24CE","Siemens LOGO! 24CEo","Siemens LOGO! 24RCE","Siemens LOGO! 24RCEo","Siemens SIPLUS LOGO! 12/24RCE","Siemens SIPLUS LOGO! 12/24RCEo","Siemens SIPLUS LOGO! 230RCE","Siemens SIPLUS LOGO! 230RCEo","Siemens SIPLUS LOGO! 24CE","Siemens SIPLUS LOGO! 24CEo","Siemens SIPLUS LOGO! 24RCE","Siemens SIPLUS LOGO! 24RCEo"],"affectedProducts":[{"vendor":"Siemens","product":"LOGO! 12/24RCE","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"LOGO! 12/24RCEo","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"LOGO! 230RCE","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"LOGO! 230RCEo","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"LOGO! 24CE","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"LOGO! 24CEo","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"LOGO! 24RCE","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"LOGO! 24RCEo","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS LOGO! 12/24RCE","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS LOGO! 12/24RCEo","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS LOGO! 230RCE","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS LOGO! 230RCEo","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24CE","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24CEo","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24RCE","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24RCEo","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-120"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-955858.pdf","tags":["x_transferred","Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-955858.html","tags":[]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total"},"epss":0.01095,"epssPercentile":0.66226,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-36361","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-36361","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-36361","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-36361","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}