{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-34764","id":"CVE-2022-34764","title":"A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could ca…","description":"A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)","descriptionLong":"A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)","published":"2022-07-13T21:11:05.954Z","updated":"2026-06-17T04:50:53.137Z","reserved":"2022-06-28T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"schneider"},"metrics":[{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"schneider"},{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"se.com"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"NVD"}],"rating":"medium","products":["Schneider Electric OPC UA Modicon Communication Module","Schneider Electric X80 advanced RTU Communication Module"],"affectedProducts":[{"vendor":"Schneider Electric","product":"OPC UA Modicon Communication Module","defaultStatus":null,"versions":[{"lessThan":"V1.10","status":"affected","version":"BMENUA0100","versionType":"custom"}],"platforms":[]},{"vendor":"Schneider Electric","product":"X80 advanced RTU Communication Module","defaultStatus":null,"versions":[{"status":"affected","version":"BMENOR2200H V1.0"}],"platforms":[]}],"packages":[],"cwes":["CWE-119"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf","tags":["x_refsource_MISC","x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00707,"epssPercentile":0.54151,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-34764","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-34764","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-34764","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-34764","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}