{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-32748","id":"CVE-2022-32748","title":"A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data…","description":"A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Version","descriptionLong":"A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)","published":"2023-01-30T00:00:00.000Z","updated":"2026-06-17T04:47:50.963Z","reserved":"2022-06-09T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":7.9,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"schneider"},"metrics":[{"version":"3.1","score":7.9,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"schneider"},{"version":"3.1","score":7.9,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"se.com"},{"version":"3.1","score":8.3,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","rating":"high","source":"NVD"}],"rating":"high","products":["Schneider Electric EcoStruxure™ Cybersecurity Admin Expert (CAE)"],"affectedProducts":[{"vendor":"Schneider Electric","product":"EcoStruxure™ Cybersecurity Admin Expert (CAE)","defaultStatus":null,"versions":[{"version":"All","status":"affected","lessThan":"2.2","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-295"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf","tags":["x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.00144,"epssPercentile":0.0376,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-32748","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-32748","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-32748","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-32748","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}