{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-31807","id":"CVE-2022-31807","title":"Building X - Security Manager Edge Controller (ACC-AP) (All versions): upload a maliciously modified firmware onto th…","description":"A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the de","descriptionLong":"A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware \"on the fly\".","published":"2025-05-23T15:03:38.535Z","updated":"2026-06-17T04:46:20.877Z","reserved":"2022-05-30T10:21:52.586Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"4.0","score":5.9,"vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","rating":"medium","source":"siemens"},"metrics":[{"version":"4.0","score":5.9,"vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","rating":"medium","source":"siemens"},{"version":"4.0","score":5.9,"vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","rating":"medium","source":"siemens.com"},{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","rating":"medium","source":"siemens"},{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","rating":"medium","source":"siemens.com"},{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N","rating":"medium","source":"NVD"}],"rating":"medium","products":["Siemens Building X - Security Manager Edge Controller (ACC-AP)"],"affectedProducts":[{"vendor":"Siemens","product":"Building X - Security Manager Edge Controller (ACC-AP)","defaultStatus":"unknown","versions":[{"status":"affected","version":"0","lessThan":"*","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-347"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-367714.html","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-420375.html","tags":[]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00163,"epssPercentile":0.05573,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-31807","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-31807","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-31807","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-31807","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}