Cranelift vulnerable to miscompilation of constant values in division on AArch64
bytecodealliance wasmtime
Affected versions
| Product | Affected | Fixed in |
|---|---|---|
| wasmtime crates.io |
|
|
bytecodealliance wasmtime
| Product | Affected | Fixed in |
|---|---|---|
| wasmtime crates.io |
|
|
| cranelift-codegen crates.io |
|
|
Wasmtime is a standalone runtime for WebAssembly. There is a bug in Wasmtime's code generator, Cranelift, for AArch64 targets where constant divisors can result in incorrect division results at runtime. This affects Wasmtime prior to version 0.38.2 and Cranelift prior to 0.85.2. This issue only affects the AArch64 platform. Other platforms are not affected. The translation rules for constants did not take into account whether sign or zero-extension should happen which resulted in an incorrect value being placed into a register when a division was encountered. The impact of this bug is that programs executing within the WebAssembly sandbox would not behave according to the WebAssembly specification. This means that it is hypothetically possible for execution within the sandbox to go awry and WebAssembly programs could produce unexpected results. This should not impact hosts executing WebAssembly but does affect the correctness of guest programs. This bug has been patched in Wasmtime version 0.38.2 and cranelift-codegen 0.85.2. There are no known workarounds.
From the CVE record · GitHub_M
On AArch64, a bug in Cranelift can produce incorrect division results when WebAssembly programs use constant divisors. Guest programs may produce unexpected results, but hosts executing WebAssembly should not be affected. The input does not specify authentication, network access, or user-interaction requirements.
Engineers running Wasmtime before 0.38.2 or cranelift-codegen before 0.85.2 on AArch64 should check their deployments.