{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-2988","id":"CVE-2022-2988","title":"A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a m…","description":"A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0)","descriptionLong":"A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0)","published":"2023-01-30T00:00:00.000Z","updated":"2026-06-17T04:42:56.300Z","reserved":"2022-08-25T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":4.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","rating":"medium","source":"schneider"},"metrics":[{"version":"3.1","score":4.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","rating":"medium","source":"schneider"},{"version":"3.1","score":4.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","rating":"medium","source":"se.com"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","rating":"high","source":"NVD"}],"rating":"medium","products":["Schneider Electric SoMachine HVAC","Schneider Electric EcoStruxure Machine Expert – HVAC"],"affectedProducts":[{"vendor":"Schneider Electric","product":"SoMachine HVAC","defaultStatus":null,"versions":[{"version":"All","status":"affected","lessThan":"V2.1.0","versionType":"custom"}],"platforms":[]},{"vendor":"Schneider Electric","product":"EcoStruxure Machine Expert – HVAC","defaultStatus":null,"versions":[{"version":"All","status":"affected","lessThan":"V1.4.0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-787"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf","tags":["x_transferred","Release Notes","Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"partial"},"epss":0.00434,"epssPercentile":0.38435,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-2988","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-2988","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-2988","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-2988","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}