{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-26647","id":"CVE-2022-26647","title":"SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO…","description":"A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.","descriptionLong":"A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.","published":"2022-07-12T10:06:32.000Z","updated":"2026-06-17T04:35:34.777Z","reserved":"2022-03-07T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","rating":"high","source":"siemens"},"metrics":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C","rating":"high","source":"siemens"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"siemens.com"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"NVD"},{"version":"2.0","score":7.5,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","rating":"high","source":"NVD"}],"rating":"high","products":["Siemens SCALANCE X200-4P IRT","Siemens SCALANCE X201-3P IRT","Siemens SCALANCE X201-3P IRT PRO","Siemens SCALANCE X202-2IRT","Siemens SCALANCE X202-2P IRT","Siemens SCALANCE X202-2P IRT PRO","Siemens SCALANCE X204-2","Siemens SCALANCE X204-2FM","Siemens SCALANCE X204-2LD","Siemens SCALANCE X204-2LD TS","Siemens SCALANCE X204-2TS","Siemens SCALANCE X204IRT","Siemens SCALANCE X204IRT PRO","Siemens SCALANCE X206-1","Siemens SCALANCE X206-1LD","Siemens SCALANCE X208","Siemens SCALANCE X208PRO","Siemens SCALANCE X212-2","Siemens SCALANCE X212-2LD","Siemens SCALANCE X216","Siemens SCALANCE X224","Siemens SCALANCE XF201-3P IRT","Siemens SCALANCE XF202-2P IRT","Siemens SCALANCE XF204","Siemens SCALANCE XF204-2","Siemens SCALANCE XF204-2BA IRT","Siemens SCALANCE XF204IRT","Siemens SCALANCE XF206-1","Siemens SCALANCE XF208"],"affectedProducts":[{"vendor":"Siemens","product":"SCALANCE X200-4P IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X201-3P IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X201-3P IRT PRO","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X202-2IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X202-2IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X202-2P IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X202-2P IRT PRO","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X204-2","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X204-2FM","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X204-2LD","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X204-2LD TS","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X204-2TS","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X204IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X204IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X204IRT PRO","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X206-1","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X206-1LD","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X208","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X208PRO","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X212-2","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X212-2LD","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X216","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE X224","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE XF201-3P IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE XF202-2P IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE XF204","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE XF204-2","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE XF204-2BA IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE XF204IRT","defaultStatus":"unknown","versions":[{"version":"All versions < V5.5.2","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE XF206-1","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]},{"vendor":"Siemens","product":"SCALANCE XF208","defaultStatus":"unknown","versions":[{"version":"All versions < V5.2.6","status":"affected"}],"platforms":[]}],"packages":[],"cwes":["CWE-330"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf","tags":["x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"no","technicalImpact":"total"},"epss":0.012,"epssPercentile":0.68843,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-26647","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-26647","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-26647","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-26647","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}