{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2022-24311","id":"CVE-2022-24311","title":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modificat…","description":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0","descriptionLong":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","published":"2022-02-09T22:04:58.000Z","updated":"2026-06-17T04:31:35.953Z","reserved":"2022-02-02T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"NVD"},"metrics":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"NVD"},{"version":"2.0","score":7.5,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","rating":"high","source":"NVD"}],"rating":"critical","products":["Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)"],"affectedProducts":[{"vendor":"n/a","product":"Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","defaultStatus":null,"versions":[{"status":"affected","version":"Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)"}],"platforms":[]}],"packages":[],"cwes":["CWE-22"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-01","tags":["x_refsource_MISC","x_transferred","Patch","Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-22-320/","tags":["x_refsource_MISC","x_transferred","Patch","Third Party Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.03505,"epssPercentile":0.89429,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2022-24311","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2022-24311","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2022-24311","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2022-24311","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}