{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2021-40407","id":"CVE-2021-40407","title":"An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.…","description":"An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->domain variable, that has the value of the domain parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection. An attacker can send an HTTP request to trigger this vulner","descriptionLong":"An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->domain variable, that has the value of the domain parameter provided through the SetDdns API, is not validated properly. This would lead to an OS command injection. An attacker can send an HTTP request to trigger this vulnerability.","published":"2022-01-28T19:10:13.000Z","updated":"2026-06-17T04:06:52.767Z","reserved":"2021-09-01T00:00:00.000Z","status":"Analyzed","rejected":false,"assigner":"talos","metric":{"version":"3.1","score":7.2,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"},"metrics":[{"version":"3.1","score":7.2,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"},{"version":"3.0","score":9.1,"vector":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"talos"},{"version":"3.0","score":9.1,"vector":"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"cisco.com"},{"version":"2.0","score":7.5,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:P","rating":"high","source":"NVD"}],"rating":"high","products":[],"affectedProducts":[{"vendor":"n/a","product":"n/a","defaultStatus":null,"versions":[{"status":"affected","version":"n/a"}],"platforms":[]}],"packages":[],"cwes":["CWE-78"],"aliases":[],"references":[{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2021-1424","tags":["x_refsource_MISC","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-40407","tags":["government-resource","US Government Resource"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":true,"kev":true,"kevAdded":"2024-12-18","kevDue":"2025-01-08","kevEntry":{"cveID":"CVE-2021-40407","vendorProject":"Reolink","product":"RLC-410W IP Camera","vulnerabilityName":"Reolink RLC-410W IP Camera OS Command Injection Vulnerability","dateAdded":"2024-12-18","shortDescription":"Reolink RLC-410W IP cameras contain an authenticated OS command injection vulnerability in the device network settings functionality.","requiredAction":"The impacted product could be end-of-life (EoL) and/or end-of-service (EoS). Users should discontinue product utilization if a current mitigation is unavailable.","dueDate":"2025-01-08","knownRansomwareCampaignUse":"Unknown","notes":"https://reolink.com/product-eol/ ; https://reolink.com/download-center/ ; https://nvd.nist.gov/vuln/detail/CVE-2021-40407","cwes":["CWE-78"]},"ssvc":{"exploitation":"active","automatable":"no","technicalImpact":"total"},"epss":0.47635,"epssPercentile":0.98871,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2021-40407","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2021-40407","ok":true,"note":"Analyzed"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2021-40407","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"added 2024-12-18"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2021-40407","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":["Exploited in the wild (CISA KEV)","EPSS 48% with CVSS 7.2"],"attention":null}