{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2021-35533","id":"CVE-2021-35533","title":"Specially Crafted IEC 60870-5-104 Packet Vulnerability in RTU500 series","description":"Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi","descriptionLong":"Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions).","published":"2021-11-26T16:37:27.683Z","updated":"2026-06-17T03:57:39.317Z","reserved":"2021-06-28T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"Hitachi Energy","metric":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"Hitachi Energy"},"metrics":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"Hitachi Energy"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"hitachienergy.com"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"NVD"},{"version":"2.0","score":7.1,"vector":"AV:N/AC:M/Au:N/C:N/I:N/A:C","rating":"high","source":"NVD"}],"rating":"high","products":["Hitachi Energy RTU500 series"],"affectedProducts":[{"vendor":"Hitachi Energy","product":"RTU500 series","defaultStatus":null,"versions":[{"lessThanOrEqual":"12.0.*","status":"affected","version":"CMU Firmware version 12.0","versionType":"custom"},{"lessThanOrEqual":"12.2.*","status":"affected","version":"CMU Firmware version 12.2","versionType":"custom"},{"lessThanOrEqual":"12.4.*","status":"affected","version":"CMU Firmware version 12.4","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-20"],"aliases":[],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000063&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.0095,"epssPercentile":0.61996,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2021-35533","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2021-35533","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2021-35533","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2021-35533","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}