{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2021-31892","id":"CVE-2021-31892","title":"SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPer…","description":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUME","descriptionLong":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.","published":"2021-07-13T11:02:55.000Z","updated":"2026-06-17T03:52:26.303Z","reserved":"2021-04-29T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"3.1","score":7.4,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","rating":"high","source":"NVD"},"metrics":[{"version":"3.1","score":7.4,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","rating":"high","source":"NVD"},{"version":"2.0","score":5.8,"vector":"AV:N/AC:M/Au:N/C:P/I:P/A:N","rating":"medium","source":"NVD"}],"rating":"high","products":["Siemens SINUMERIK Analyse MyCondition","Siemens SINUMERIK Analyze MyPerformance","Siemens SINUMERIK Analyze MyPerformance /OEE-Monitor","Siemens SINUMERIK Analyze MyPerformance /OEE-Tuning","Siemens SINUMERIK Integrate Client 02","Siemens SINUMERIK Integrate Client 03","Siemens SINUMERIK Integrate Client 04","Siemens SINUMERIK Integrate for Production 4.1","Siemens SINUMERIK Integrate for Production 5.1","Siemens SINUMERIK Manage MyMachines","Siemens SINUMERIK Manage MyMachines /Remote","Siemens SINUMERIK Manage MyMachines /Spindel Monitor","Siemens SINUMERIK Manage MyPrograms","Siemens SINUMERIK Manage MyResources /Programs","Siemens SINUMERIK Manage MyResources /Tools","Siemens SINUMERIK Manage MyTools","Siemens SINUMERIK Operate V4.8","Siemens SINUMERIK Operate V4.93","Siemens SINUMERIK Operate V4.94","Siemens SINUMERIK Optimize MyProgramming /NX-Cam Editor"],"affectedProducts":[{"vendor":"Siemens","product":"SINUMERIK Analyse MyCondition","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance /OEE-Monitor","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance /OEE-Tuning","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 02","defaultStatus":null,"versions":[{"status":"affected","version":"All versions >= V02.00.12 < 02.00.18"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 03","defaultStatus":null,"versions":[{"status":"affected","version":"All versions >= V03.00.12 < 03.00.18"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 04","defaultStatus":null,"versions":[{"status":"affected","version":"V04.00.02 and all versions >= V04.00.15 < 04.00.18"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Integrate for Production 4.1","defaultStatus":null,"versions":[{"status":"affected","version":"All versions < V4.1 SP10 HF3"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Integrate for Production 5.1","defaultStatus":null,"versions":[{"status":"affected","version":"V5.1"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines /Remote","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines /Spindel Monitor","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Manage MyPrograms","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Manage MyResources /Programs","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Manage MyResources /Tools","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Manage MyTools","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Operate V4.8","defaultStatus":null,"versions":[{"status":"affected","version":"All versions < V4.8 SP8"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Operate V4.93","defaultStatus":null,"versions":[{"status":"affected","version":"All versions < V4.93 HF7"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Operate V4.94","defaultStatus":null,"versions":[{"status":"affected","version":"All versions < V4.94 HF5"}],"platforms":[]},{"vendor":"Siemens","product":"SINUMERIK Optimize MyProgramming /NX-Cam Editor","defaultStatus":null,"versions":[{"status":"affected","version":"All versions"}],"platforms":[]}],"packages":[],"cwes":["CWE-295"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04","tags":["x_refsource_MISC","x_transferred","Third Party Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00486,"epssPercentile":0.42746,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2021-31892","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2021-31892","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2021-31892","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2021-31892","ok":true,"note":"scored 2026-11-20"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}