{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2021-23857","id":"CVE-2021-23857","title":"Login with hash","description":"Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system.","descriptionLong":"Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system.","published":"2021-10-04T17:32:36.000Z","updated":"2026-06-17T03:38:56.737Z","reserved":"2021-01-12T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"bosch","metric":{"version":"3.1","score":10,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"bosch"},"metrics":[{"version":"3.1","score":10,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"bosch"},{"version":"3.1","score":10,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","rating":"critical","source":"bosch.com"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"critical","source":"NVD"},{"version":"2.0","score":10,"vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","rating":"critical","source":"NVD"}],"rating":"critical","products":["Rexroth IndraMotion MLC L25, L45, L65, L75, L85, XM21, XM22, XM41 and XM42 IndraMotion XLC","Rexroth IndraMotion MLC L20, L40"],"affectedProducts":[{"vendor":"Rexroth","product":"IndraMotion MLC L25, L45, L65, L75, L85, XM21, XM22, XM41 and XM42 IndraMotion XLC","defaultStatus":null,"versions":[{"lessThan":"unspecified","status":"affected","version":"12 VRS","versionType":"custom"}],"platforms":[]},{"vendor":"Rexroth","product":"IndraMotion MLC L20, L40","defaultStatus":null,"versions":[{"lessThan":"unspecified","status":"affected","version":"12 VRS","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-836","CWE-287"],"aliases":[],"references":[{"url":"https://psirt.bosch.com/security-advisories/bosch-sa-741752.html","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.01234,"epssPercentile":0.69642,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2021-23857","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2021-23857","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2021-23857","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2021-23857","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}