{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2021-22764","id":"CVE-2021-22764","title":"A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 an…","description":"A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.","descriptionLong":"A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.","published":"2021-06-11T15:40:47.000Z","updated":"2026-06-17T03:37:43.843Z","reserved":"2021-01-06T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","rating":"medium","source":"NVD"},"metrics":[{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","rating":"medium","source":"NVD"},{"version":"3.1","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L","rating":"medium","source":"CISA-ADP"},{"version":"2.0","score":5,"vector":"AV:N/AC:L/Au:N/C:N/I:N/A:P","rating":"medium","source":"NVD"}],"rating":"medium","products":["PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)"],"affectedProducts":[{"vendor":"n/a","product":"PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)","defaultStatus":"unaffected","versions":[{"status":"affected","version":"PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)"}],"platforms":[]}],"packages":[],"cwes":["CWE-287"],"aliases":[],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-159-02.pdf","tags":["x_refsource_MISC"]},{"url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02%2Chttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03","tags":["x_refsource_MISC","x_transferred"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"partial"},"epss":0.01858,"epssPercentile":0.79672,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2021-22764","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22764","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2021-22764","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2021-22764","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}