{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2021-22709","id":"CVE-2021-22709","title":"A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive…","description":"A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.","descriptionLong":"A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.","published":"2021-03-11T20:27:13.000Z","updated":"2026-06-17T03:37:36.437Z","reserved":"2021-01-06T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"schneider","metric":{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"},"metrics":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"},{"version":"2.0","score":9.3,"vector":"AV:N/AC:M/Au:N/C:C/I:C/A:C","rating":"critical","source":"NVD"}],"rating":"high","products":["Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior"],"affectedProducts":[{"vendor":"n/a","product":"Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior","defaultStatus":null,"versions":[{"status":"affected","version":"Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior"}],"platforms":[]}],"packages":[],"cwes":["CWE-119"],"aliases":[],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2021-068-01","tags":["x_refsource_MISC","x_transferred","Broken Link","Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01","tags":["x_refsource_MISC","x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.02219,"epssPercentile":0.83039,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2021-22709","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22709","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2021-22709","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2021-22709","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}