{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2021-22284","id":"CVE-2021-22284","title":"SECURITY - OPC Server for AC 800M - Remote Code Execution Vulnerability","description":"Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server.","descriptionLong":"Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server.","published":"2022-02-04T22:29:21.143Z","updated":"2026-06-17T03:36:56.273Z","reserved":"2021-01-05T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"ABB","metric":{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"ABB"},"metrics":[{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"ABB"},{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","rating":"high","source":"ch.abb.com"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","rating":"high","source":"NVD"},{"version":"2.0","score":6.5,"vector":"AV:N/AC:L/Au:S/C:P/I:P/A:P","rating":"medium","source":"NVD"}],"rating":"high","products":["ABB 800xA, Control Software for AC 800M OPC Server for AC 800M","ABB Control Builder Safe, version 1.x OPC Server for AC 800M","ABB Control Builder Safe, version 2.0 OPC Server for AC 800M","ABB Compact Product Suite - Control and I/O OPC Server for AC 800M"],"affectedProducts":[{"vendor":"ABB","product":"800xA, Control Software for AC 800M OPC Server for AC 800M","defaultStatus":null,"versions":[{"lessThanOrEqual":"5.1.0-x","status":"affected","version":"unspecified","versionType":"custom"},{"lessThanOrEqual":"5.1.1-x","status":"affected","version":"unspecified","versionType":"custom"},{"status":"affected","version":"6.0.0-1"},{"status":"affected","version":"6.0.0-2"},{"status":"affected","version":"6.0.0-3"}],"platforms":[]},{"vendor":"ABB","product":"Control Builder Safe, version 1.x OPC Server for AC 800M","defaultStatus":null,"versions":[{"status":"affected","version":"5.1.1-1"}],"platforms":[]},{"vendor":"ABB","product":"Control Builder Safe, version 2.0 OPC Server for AC 800M","defaultStatus":null,"versions":[{"status":"affected","version":"6.0.0-1"}],"platforms":[]},{"vendor":"ABB","product":"Compact Product Suite - Control and I/O OPC Server for AC 800M","defaultStatus":null,"versions":[{"lessThanOrEqual":"5.1.0-x","status":"affected","version":"unspecified","versionType":"custom"},{"lessThanOrEqual":"5.1.1-x","status":"affected","version":"unspecified","versionType":"custom"},{"lessThanOrEqual":"6.0.0-x","status":"affected","version":"unspecified","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-732"],"aliases":[],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=7PAA000908&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00831,"epssPercentile":0.58341,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2021-22284","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2021-22284","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2021-22284","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2021-22284","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}