{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2021-20599","id":"CVE-2021-20599","title":"Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSE…","description":"Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than pass","descriptionLong":"Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password.","published":"2021-10-14T00:00:00.000Z","updated":"2026-06-17T03:34:05.783Z","reserved":"2020-12-17T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"Mitsubishi","metric":{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","rating":"critical","source":"Mitsubishi"},"metrics":[{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","rating":"critical","source":"Mitsubishi"},{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","rating":"critical","source":"yd.MitsubishiElectric.co.jp"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","rating":"high","source":"NVD"},{"version":"2.0","score":5,"vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","rating":"medium","source":"NVD"}],"rating":"critical","products":["Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08SFCPU","Mitsubishi Electric Corporation MELSEC iQ-R series Safety CPU R16SFCPU","Mitsubishi Electric Corporation MELSEC iQ-R series Safety CPU R32SFCPU","Mitsubishi Electric Corporation MELSEC iQ-R series Safety CPU R120SFCPU","Mitsubishi Electric Corporation MELSEC iQ-R Series SIL2 Process CPU R08PSFCPU","Mitsubishi Electric Corporation MELSEC iQ-R series SIL2 Process CPU R16PSFCPU","Mitsubishi Electric Corporation MELSEC iQ-R series SIL2 Process CPU R32PSFCPU","Mitsubishi Electric Corporation MELSEC iQ-R series SIL2 Process CPU R120PSFCPU"],"affectedProducts":[{"vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series Safety CPU R08SFCPU","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Firmware versions \"26\" and prior"}],"platforms":[]},{"vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R series Safety CPU R16SFCPU","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Firmware versions \"26\" and prior"}],"platforms":[]},{"vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R series Safety CPU R32SFCPU","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Firmware versions \"26\" and prior"}],"platforms":[]},{"vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R series Safety CPU R120SFCPU","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Firmware versions \"26\" and prior"}],"platforms":[]},{"vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R Series SIL2 Process CPU R08PSFCPU","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Firmware versions \"11\" and prior"}],"platforms":[]},{"vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R series SIL2 Process CPU R16PSFCPU","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Firmware versions \"11\" and prior"}],"platforms":[]},{"vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R series SIL2 Process CPU R32PSFCPU","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Firmware versions \"11\" and prior"}],"platforms":[]},{"vendor":"Mitsubishi Electric Corporation","product":"MELSEC iQ-R series SIL2 Process CPU R120PSFCPU","defaultStatus":"unaffected","versions":[{"status":"affected","version":"Firmware versions \"11\" and prior"}],"platforms":[]}],"packages":[],"cwes":["CWE-319","CWE-639"],"aliases":[],"references":[{"url":"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf","tags":["vendor-advisory","x_transferred","Vendor Advisory"]},{"url":"https://jvn.jp/vu/JVNVU98578731","tags":["government-resource","x_transferred","Third Party Advisory"]},{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03","tags":["government-resource","x_transferred"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":{"exploitation":"none","automatable":"yes","technicalImpact":"total"},"epss":0.01402,"epssPercentile":0.73201,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2021-20599","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2021-20599","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2021-20599","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2021-20599","ok":true,"note":"scored 2026-11-20"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}