{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2020-16228","id":"CVE-2020-16228","title":"Philips Patient Monitoring Devices Improper Check for Certificate Revocation","description":"In Patient Information Center iX (PICiX) Versions C.02 and C.03, \nPerformanceBridge Focal Point Version A.01, IntelliVue patient monitors \nMX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and \nprior, the software does not check or incorrectly checks the revocation \nstatus of a certificate, which may cause it to use a compromised \ncertificate.","descriptionLong":"In Patient Information Center iX (PICiX) Versions C.02 and C.03, \nPerformanceBridge Focal Point Version A.01, IntelliVue patient monitors \nMX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and \nprior, the software does not check or incorrectly checks the revocation \nstatus of a certificate, which may cause it to use a compromised \ncertificate.","published":"2020-09-11T12:58:13.000Z","updated":"2026-06-17T02:57:54.003Z","reserved":"2020-07-31T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.1","score":6.4,"vector":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L","rating":"medium","source":"NVD"},"metrics":[{"version":"3.1","score":6.4,"vector":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L","rating":"medium","source":"NVD"},{"version":"2.0","score":5.2,"vector":"AV:A/AC:L/Au:S/C:P/I:P/A:P","rating":"medium","source":"NVD"}],"rating":"medium","products":["Philips Patient Information Center iX (PICiX)","Philips PerformanceBridge Focal Point","Philips IntelliVue patient monitors","Philips IntelliVue X3"],"affectedProducts":[{"vendor":"Philips","product":"Patient Information Center iX (PICiX)","defaultStatus":"unaffected","versions":[{"status":"affected","version":"C.02"},{"status":"affected","version":"C.03"}],"platforms":[]},{"vendor":"Philips","product":"PerformanceBridge Focal Point","defaultStatus":"unaffected","versions":[{"status":"affected","version":"A.01"}],"platforms":[]},{"vendor":"Philips","product":"IntelliVue patient monitors","defaultStatus":"unaffected","versions":[{"status":"affected","version":"MX100"},{"status":"affected","version":"MX400-MX550"},{"status":"affected","version":"MX750"},{"status":"affected","version":"MX850"}],"platforms":[]},{"vendor":"Philips","product":"IntelliVue X3","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"N","status":"affected","version":"0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-299"],"aliases":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://www.philips.com/productsecurity","tags":["x_transferred"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00368,"epssPercentile":0.31348,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2020-16228","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2020-16228","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2020-16228","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2020-16228","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}