{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2020-16216","id":"CVE-2020-16216","title":"Philips Patient Monitoring Devices Improper Input Validation","description":"In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, \nMX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, \nthe product receives input or data but does not validate or incorrectly \nvalidates that the input has the properties required to process the data\n safely and correctly, which can induce a denial-of-service condition \nthrough a system restart.","descriptionLong":"In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, \nMX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, \nthe product receives input or data but does not validate or incorrectly \nvalidates that the input has the properties required to process the data\n safely and correctly, which can induce a denial-of-service condition \nthrough a system restart.","published":"2020-09-11T13:06:55.000Z","updated":"2026-06-17T02:57:52.513Z","reserved":"2020-07-31T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"NVD"},"metrics":[{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"medium","source":"NVD"},{"version":"2.0","score":6.1,"vector":"AV:A/AC:L/Au:N/C:N/I:N/A:C","rating":"medium","source":"NVD"}],"rating":"medium","products":["Philips IntelliVue patient monitors","Philips IntelliVue"],"affectedProducts":[{"vendor":"Philips","product":"IntelliVue patient monitors","defaultStatus":"unaffected","versions":[{"status":"affected","version":"MX100"},{"status":"affected","version":"MX400-550"},{"status":"affected","version":"MX600"},{"status":"affected","version":"MX700"},{"status":"affected","version":"MX750"},{"status":"affected","version":"MX800"},{"status":"affected","version":"MX850"},{"status":"affected","version":"MP2-MP90"}],"platforms":[]},{"vendor":"Philips","product":"IntelliVue","defaultStatus":"unaffected","versions":[{"status":"affected","version":"X2"},{"status":"affected","version":"X3"},{"lessThanOrEqual":"N","status":"affected","version":"0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-20"],"aliases":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://www.philips.com/productsecurity","tags":["x_transferred"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00698,"epssPercentile":0.53882,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2020-16216","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2020-16216","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2020-16216","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2020-16216","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}