{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2020-12013","id":"CVE-2020-12013","title":"A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely","description":"A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and pr","descriptionLong":"A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.","published":"2020-07-16T21:14:34.000Z","updated":"2026-06-17T02:51:15.247Z","reserved":"2020-04-21T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","rating":"critical","source":"NVD"},"metrics":[{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","rating":"critical","source":"NVD"},{"version":"2.0","score":6.4,"vector":"AV:N/AC:L/Au:N/C:P/I:P/A:N","rating":"medium","source":"NVD"}],"rating":"critical","products":["Mitsubishi Electric MC Works64","Mitsubishi Electric MC Works32","ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server","ICONICS GenBroker32"],"affectedProducts":[{"vendor":"Mitsubishi Electric","product":"MC Works64","defaultStatus":null,"versions":[{"status":"affected","version":"Version 4.02C (10.95.208.31) and earlier"},{"status":"affected","version":"all versions"}],"platforms":[]},{"vendor":"Mitsubishi Electric","product":"MC Works32","defaultStatus":null,"versions":[{"status":"affected","version":"Version 3.00A (9.50.255.02)"}],"platforms":[]},{"vendor":"ICONICS","product":"GenBroker64, Platform Services, Workbench, FrameWorX Server","defaultStatus":null,"versions":[{"status":"affected","version":"v10.96 and prior"}],"platforms":[]},{"vendor":"ICONICS","product":"GenBroker32","defaultStatus":null,"versions":[{"status":"affected","version":"v9.5 and prior"}],"platforms":[]}],"packages":[],"cwes":["CWE-94","CWE-89"],"aliases":[],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02","tags":["x_refsource_CONFIRM","x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03","tags":["x_refsource_CONFIRM","x_transferred","Third Party Advisory","US Government Resource"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.03029,"epssPercentile":0.87764,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2020-12013","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2020-12013","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2020-12013","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2020-12013","ok":true,"note":"scored 2026-11-19"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}