{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2019-14359","id":"CVE-2019-14359","title":"On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found","description":"On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover a data value. In other words, the side channel is relevant only if","descriptionLong":"On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover a data value. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. NOTE: the vendor's position is that there is no security impact: the only potentially leaked information is the number of characters in the PIN","published":"2019-08-12T22:31:34.000Z","updated":"2026-06-17T02:18:16.637Z","reserved":"2019-07-28T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"mitre","metric":{"version":"3.0","score":2.4,"vector":"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","rating":"low","source":"NVD"},"metrics":[{"version":"3.0","score":2.4,"vector":"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","rating":"low","source":"NVD"},{"version":"2.0","score":2.1,"vector":"AV:L/AC:L/Au:N/C:P/I:N/A:N","rating":"low","source":"NVD"}],"rating":"low","products":[],"affectedProducts":[{"vendor":"n/a","product":"n/a","defaultStatus":null,"versions":[{"status":"affected","version":"n/a"}],"platforms":[]}],"packages":[],"cwes":["CWE-203"],"aliases":[],"references":[{"url":"https://bc-vault.com/2019/08/our-response-to-cve-2019-14359","tags":["x_refsource_MISC","x_transferred","Exploit","Third Party Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":true,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00423,"epssPercentile":0.37221,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2019-14359","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2019-14359","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2019-14359","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2019-14359","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}