{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2019-13543","id":"CVE-2019-13543","title":"Medtronic Valleylab FT10 and FX8 Use of Hard-coded Credentials","description":"Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.","descriptionLong":"Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.","published":"2019-11-08T19:03:51.000Z","updated":"2026-06-17T02:16:56.823Z","reserved":"2019-07-11T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.1","score":5.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N","rating":"medium","source":"icscert"},"metrics":[{"version":"3.1","score":5.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N","rating":"medium","source":"icscert"},{"version":"3.1","score":5.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N","rating":"medium","source":"hq.dhs.gov"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","rating":"high","source":"NVD"},{"version":"2.0","score":5,"vector":"AV:N/AC:L/Au:N/C:P/I:N/A:N","rating":"medium","source":"NVD"}],"rating":"medium","products":["Medtronic Valleylab Exchange Client","Medtronic Valleylab FT10 Energy Platform (VLFT10GEN)","Medtronic Valleylab FX8 Energy Platform (VLFX8GEN)"],"affectedProducts":[{"vendor":"Medtronic","product":"Valleylab Exchange Client","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"3.4","status":"affected","version":"0","versionType":"c"}],"platforms":[]},{"vendor":"Medtronic","product":"Valleylab FT10 Energy Platform (VLFT10GEN)","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"software version 4.0.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]},{"vendor":"Medtronic","product":"Valleylab FX8 Energy Platform (VLFX8GEN)","defaultStatus":"unaffected","versions":[{"lessThanOrEqual":"software version 1.1.0","status":"affected","version":"0","versionType":"custom"}],"platforms":[]}],"packages":[],"cwes":["CWE-798"],"aliases":[],"references":[{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-19-311-02","tags":[]},{"url":"https://global.medtronic.com/xg-en/product-security/security-bulletins/valleylab-generator-rfid-vulnerabilities.html","tags":[]},{"url":"https://www.us-cert.gov/ics/advisories/icsma-19-311-02","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.02011,"epssPercentile":0.81269,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2019-13543","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2019-13543","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2019-13543","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2019-13543","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}