{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2018-8870","id":"CVE-2018-8870","title":"Medtronic MyCareLink Patient Monitor Use of Hard-coded Password","description":"Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.","descriptionLong":"Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.","published":"2018-07-02T18:00:00.000Z","updated":"2026-06-17T02:05:33.430Z","reserved":"2018-03-20T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.1","score":6.4,"vector":"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"medium","source":"icscert"},"metrics":[{"version":"3.1","score":6.4,"vector":"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"medium","source":"icscert"},{"version":"3.1","score":6.4,"vector":"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"medium","source":"hq.dhs.gov"},{"version":"3.0","score":6.8,"vector":"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","rating":"medium","source":"NVD"},{"version":"2.0","score":7.2,"vector":"AV:L/AC:L/Au:N/C:C/I:C/A:C","rating":"high","source":"NVD"}],"rating":"medium","products":["Medtronic 24950 MyCareLink Monitor","Medtronic 24952 MyCareLink Monitor"],"affectedProducts":[{"vendor":"Medtronic","product":"24950 MyCareLink Monitor","defaultStatus":"unaffected","versions":[{"status":"affected","version":"All versions"}],"platforms":[]},{"vendor":"Medtronic","product":"24952 MyCareLink Monitor","defaultStatus":"unaffected","versions":[{"status":"affected","version":"All versions"}],"platforms":[]}],"packages":[],"cwes":["CWE-259","CWE-798"],"aliases":[],"references":[{"url":"https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-6-28-18.html","tags":[]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-179-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00364,"epssPercentile":0.30828,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2018-8870","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2018-8870","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2018-8870","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2018-8870","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}