{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2018-8861","id":"CVE-2018-8861","title":"Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance…","description":"Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a limited-access kiosk user or an unauthorized attacker to break-out from the containment of the kiosk environment, attain elevated privileges from the ","descriptionLong":"Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a limited-access kiosk user or an unauthorized attacker to break-out from the containment of the kiosk environment, attain elevated privileges from the underlying Windows OS, and access unauthorized resources from the operating system.","published":"2018-05-04T17:00:00.000Z","updated":"2026-06-17T02:05:32.130Z","reserved":"2018-03-20T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.0","score":8.7,"vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L","rating":"high","source":"NVD"},"metrics":[{"version":"3.0","score":8.7,"vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L","rating":"high","source":"NVD"},{"version":"2.0","score":6.8,"vector":"AV:L/AC:L/Au:N/C:C/I:C/A:P","rating":"medium","source":"NVD"}],"rating":"high","products":["Philips Brilliance CT Scanners"],"affectedProducts":[{"vendor":"Philips","product":"Brilliance CT Scanners","defaultStatus":null,"versions":[{"status":"affected","version":"Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior."}],"platforms":[]}],"packages":[],"cwes":["CWE-668"],"aliases":[],"references":[{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","tags":["x_refsource_CONFIRM","x_transferred","Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/104088","tags":["vdb-entry","x_refsource_BID","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-123-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00398,"epssPercentile":0.34641,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2018-8861","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2018-8861","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2018-8861","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2018-8861","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}