{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2018-13798","id":"CVE-2018-13798","title":"SICAM A8000 CP-8000 (All versions < V14), SICAM A8000 CP-802X (All versions < V14), SICAM A8000 CP-8050 (All versions…","description":"A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V14), SICAM A8000 CP-802X (All versions < V14), SICAM A8000 CP-8050 (All versions < V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker wi","descriptionLong":"A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V14), SICAM A8000 CP-802X (All versions < V14), SICAM A8000 CP-8050 (All versions < V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the web server. A system reboot is required to recover the web service of the device. At the time of advisory update, exploit code for this security vulnerability is public.","published":"2019-03-21T18:48:48.000Z","updated":"2026-06-17T01:40:11.327Z","reserved":"2018-07-10T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"siemens","metric":{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"NVD"},"metrics":[{"version":"3.0","score":7.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","rating":"high","source":"NVD"},{"version":"2.0","score":7.8,"vector":"AV:N/AC:L/Au:N/C:N/I:N/A:C","rating":"high","source":"NVD"}],"rating":"high","products":["Siemens AG SICAM A8000 CP-8000, SICAM A8000 CP-802X, SICAM A8000 CP-8050","Siemens AG SICAM A8000 CP-802X","Siemens AG SICAM A8000 CP-8050"],"affectedProducts":[{"vendor":"Siemens AG","product":"SICAM A8000 CP-8000, SICAM A8000 CP-802X, SICAM A8000 CP-8050","defaultStatus":null,"versions":[{"status":"affected","version":"SICAM A8000 CP-8000 : All versions < V14"}],"platforms":[]},{"vendor":"Siemens AG","product":"SICAM A8000 CP-802X","defaultStatus":null,"versions":[{"status":"affected","version":"SICAM A8000 CP-802X : All versions < V14"}],"platforms":[]},{"vendor":"Siemens AG","product":"SICAM A8000 CP-8050","defaultStatus":null,"versions":[{"status":"affected","version":"All versions < V2.00"}],"platforms":[]}],"packages":[],"cwes":["CWE-20"],"aliases":[],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-579309.pdf","tags":["x_refsource_CONFIRM","x_transferred","Patch","Vendor Advisory"]}],"patchReferenced":true,"fixAvailable":true,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.01986,"epssPercentile":0.81013,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2018-13798","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2018-13798","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2018-13798","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2018-13798","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}