{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2018-10601","id":"CVE-2018-10601","title":"IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Mo…","description":"IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an \"echo\" service, in which an attacker-sent buffer to an attacker-chosen device address wit","descriptionLong":"IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an \"echo\" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.","published":"2018-06-05T20:00:00.000Z","updated":"2026-06-17T01:34:15.347Z","reserved":"2018-05-01T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.1","score":8.2,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H","rating":"high","source":"NVD"},"metrics":[{"version":"3.1","score":8.2,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H","rating":"high","source":"NVD"},{"version":"2.0","score":5.4,"vector":"AV:A/AC:M/Au:N/C:P/I:P/A:P","rating":"medium","source":"NVD"}],"rating":"high","products":["ICS-CERT IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors"],"affectedProducts":[{"vendor":"ICS-CERT","product":"IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors","defaultStatus":null,"versions":[{"status":"affected","version":"The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3"}],"platforms":[]}],"packages":[],"cwes":["CWE-121","CWE-787"],"aliases":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01","tags":["x_refsource_MISC","x_transferred","Third Party Advisory","US Government Resource"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00369,"epssPercentile":0.31347,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2018-10601","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2018-10601","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2018-10601","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2018-10601","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}