{"schemaVersion":1,"url":"https://cve.openhack.com/cve/CVE-2017-7907","id":"CVE-2017-7907","title":"An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 S…","description":"An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected ne","descriptionLong":"An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network.","published":"2017-05-19T02:43:00.000Z","updated":"2026-06-17T01:25:26.297Z","reserved":"2017-04-18T00:00:00.000Z","status":"Modified","rejected":false,"assigner":"icscert","metric":{"version":"3.0","score":6.6,"vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H","rating":"medium","source":"NVD"},"metrics":[{"version":"3.0","score":6.6,"vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H","rating":"medium","source":"NVD"},{"version":"2.0","score":3.3,"vector":"AV:L/AC:M/Au:N/C:P/I:N/A:P","rating":"low","source":"NVD"}],"rating":"medium","products":["Schneider Electric Wonderware Historian Client"],"affectedProducts":[{"vendor":"n/a","product":"Schneider Electric Wonderware Historian Client","defaultStatus":null,"versions":[{"status":"affected","version":"Schneider Electric Wonderware Historian Client"}],"platforms":[]}],"packages":[],"cwes":["CWE-611"],"aliases":[],"references":[{"url":"http://www.securityfocus.com/bid/98254","tags":["vdb-entry","x_refsource_BID","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"http://www.securitytracker.com/id/1038542","tags":["vdb-entry","x_refsource_SECTRACK","x_transferred"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-122-01","tags":["x_refsource_MISC","x_transferred","Mitigation","Third Party Advisory","US Government Resource"]},{"url":"http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000120/","tags":["x_refsource_MISC","x_transferred","Vendor Advisory"]}],"patchReferenced":false,"fixAvailable":false,"exploitReferenced":false,"kev":false,"kevAdded":null,"kevDue":null,"kevEntry":null,"ssvc":null,"epss":0.00388,"epssPercentile":0.33573,"sources":[{"name":"CVE List","url":"https://www.cve.org/CVERecord?id=CVE-2017-7907","ok":true},{"name":"NVD","url":"https://nvd.nist.gov/vuln/detail/CVE-2017-7907","ok":true,"note":"Modified"},{"name":"OSV","url":"https://osv.dev/vulnerability/CVE-2017-7907","ok":false,"note":"no open-source package data"},{"name":"CISA KEV","url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","ok":true,"note":"not listed"},{"name":"EPSS","url":"https://api.first.org/data/v1/epss?cve=CVE-2017-7907","ok":true,"note":"scored 2026-11-18"}],"aiTitle":false,"tech":[],"critical":[],"attention":null}